Journal of Chromatographic Science · 2023 · 10 citations · 25 references
PharmacyPharmaceutical AnalysisPharmacologyAnalytical ChemistryChromatographic AnalysisPharmaceutical TechnologyAnalytical Method ValidationBioanalytical Method ValidationChromatographic Analysis Of PharmaceuticalsChromatographyLiquid ChromatographyMetabolite QuantificationHigh-performance Liquid ChromatographyHigh-performance Liquid Chromatography AnalysisMetabolite Assay DevelopmentPharmaceutical Analysis CouplingQuantitative Analysis Using Coupled ChromatographyReverse-phase ChromatographyReverse-phase Liquid Chromatography
Many analytical methods are reported for simultaneous estimation of pharmaceutical dosages form. However, only a few are reproducible at an industrial scale. The proposed research aims to establish a technology transfer (TT) protocol between two laboratories (Lab-X, originator) with binary and (Lab-Y, receiver) with quaternary high-performance liquid chromatography (HPLC) system. Thus, utilizing reverse-phase HPLC (RP-HPLC), a robust, sensitive and repeatable analytical method has been developed, validated and TT between two laboratories for simultaneous estimation of Andrographolide (AG) and Paclitaxel (PTX). The method has been developed on a Phenomenex Luna C18 column (150 x 4.6, 5) sustained at 40°C and validated under the International Conference on Harmonisation (ICH) Q2 (R1) regulatory guideline and TT USP chapter 1224. The mobile phase consisted of MilliQ (pH = 3) and a combination of acetonitrile and methanol (1:1) in the ratio 50:50 with a flow rate of 0.45 mL/min, linear gradient elution in both labs. The AG and PTX were detected on the PDA detector at 224 and 227 nm wavelength with retention time of 4.5 ± 0.34 and 8.2 ± 0.02 min and limit of detection was found 0.028 ± 0.004 μg/mL, and 0.028 ± 0.0007 μg/mL, whereas limit of quantification as 0.086 ± 0.011 μg/mL and 0.088 ± 0.0014 μg/mL respectively in both labs. Throughout, this approach we have proved that proposed method is repeatable in both labs, and it can be used to quantify AG and PTX in developed pharmaceutical nano-formulations.
25
Alfred W. Alberts, J Chen, G. W. Kuron et al. · Proceedings of the National Academy of Sciences · 1980 · 1.6K citations · Full text
Nora A. AlFaris, Saikh Mohammad Wabaidur, Zeid A. ALOthman et al. · Journal of Separation Science · 2020 · 105 citations
Formulation and evaluation of chitosan solid lipid nanoparticles of carbamazepine
Rahul Nair, Ashok CK Kumar, Vishnu Priya et al. · Lipids in Health and Disease · 2012 · 100 citations · Full text