Journal of neurosurgery · 2023 · 20 citations · 24 references
MedicineNeurosurgerySurgeryCerebrovascular NeurosurgeryCerebrovascular SurgeryVascular SurgeryAneurysm RepairAneurysm SurgeryCerebrovascular DiseaseThrombosisThrombosis ManagementThrombosis PreventionDevice EmbolizationPrimary Outcome AnalysisRetrospective Record ReviewRuptured Aneurysm ManagementSafety Profile CharacterizationSafety Profile ReviewUnruptured Aneurysm ManagementUnruptured Intracranial Aneurysm Management
OBJECTIVE: The object of this study was to compare the efficacy and safety profile of the Pipeline embolization device (PED)/Pipeline Flex embolization device (PED Flex) with that of the Pipeline Flex embolization device with Shield Technology (PED Shield). After introducing the first-generation PED and the second-generation PED Flex with its updated delivery system, the PED Shield was launched with a synthetic layer of phosphorylcholine surface modification to reduce thrombogenicity. METHODS: This is a retrospective review of unruptured aneurysms treated with PED/PED Flex versus PED Shield between 2017 and 2022 at the authors' institution. Patients with ruptured aneurysms, adjunctive treatment, failed flow diverter deployment, and prior treatment of the target aneurysm were excluded. Baseline characteristics were collected for all patients, including age, sex, past medical history (hypertension, hyperlipidemia, diabetes mellitus), smoking status, aneurysm location, and aneurysm dimensions (neck, width, height) and morphology (saccular, nonsaccular). The primary outcome was procedural and periprocedural complication rates. RESULTS: The study cohort comprised 200 patients with 200 aneurysms, including 150 aneurysms treated with the PED/PED Flex and 50 treated with the PED Shield. With respect to intraprocedural and periprocedural complications, length of stay, length of follow-up, and functional outcome at discharge, there was no significant difference between the two cohorts. At the midterm follow-up, the rate of in-stent stenosis (PED/PED Flex: 14.2% vs PED Shield: 14.6%, p = 0.927), aneurysm occlusion (complete occlusion: 79.5% vs 80.5%, respectively; neck remnant: 4.7% vs 12.2%; dome remnant: 15.7% vs 7.3%; p = 0.119), and the need for retreatment (5.3% vs 0%, p = 0.097) were comparable between the two cohorts. CONCLUSIONS: This study suggests that, as compared to first- and second-generation PED and PED Flex, the third-generation PED Shield offers similar rates of complications, aneurysm occlusion, and in-stent stenosis at the midterm follow-up.
24
Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial
Tibor Becske, David F. Kallmes, Cameron G. McDougall et al. · Radiology · 2013 · 1.1K citations · Full text
Medicine, Neurosurgery, Surgery +17
Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)
David F Kallmes, Waleed Brinjikji, Edoardo Boccardi et al. · Interventional Neurology · 2016 · 208 citations · Full text
Medicine, Neurosurgery, Surgery +16
Current Treatment Strategies for Intracranial Aneurysms: An Overview
Junjie Zhao, Hao Lin, Richard Summers et al. · Angiology · 2017 · 177 citations · Full text
Medicine, Neurosurgery, Surgery +16