Journal of Synchrotron Radiation · 2023 · 18 citations · 33 references
Natural SciencesPhysicsDiagnostic ImagingDigital ImagingOpticsX-ray CrystallographyX-ray Data AnalysisX-ray DetectionX-ray DetectorsX-ray DiffractionX-ray OpticsDiffraction Data CollectionDiffraction ImagingDiffraction Pattern AnalysisHigh-resolution X-ray DiffractionHigh-resolution X-ray ImagingPhase SensitivityX-ray Imaging PerformanceX-ray Imaging Physics
Ptychographic coherent diffraction imaging (PCDI) is a synchrotron X-ray microscopy technique that provides high spatial resolution and a wide field of view. To improve the performance of PCDI, the performance of the synchrotron radiation source and imaging detector should be improved. In this study, ptychographic diffraction pattern measurements using the CITIUS high-speed X-ray image detector and the corresponding image reconstruction are reported. X-rays with an energy of 6.5 keV were focused by total reflection focusing mirrors, and a flux of ∼2.6 × 10 10 photons s −1 was obtained at the sample plane. Diffraction intensity data were collected at up to ∼250 Mcounts s −1 pixel −1 without saturation of the detector. Measurements of tantalum test charts and silica particles and the reconstruction of phase images were performed. A resolution of ∼10 nm and a phase sensitivity of ∼0.01 rad were obtained. The CITIUS detector can be applied to the PCDI observation of various samples using low-emittance synchrotron radiation sources and to the stability evaluation of light sources.
33
Hard-X-Ray Lensless Imaging of Extended Objects
J. M. Rodenburg, A C Hurst, A. G. Cullis et al. · Physical Review Letters · 2007 · 846 citations · Full text
Franz Pfeiffer · Nature Photonics · 2017 · 669 citations · Full text
Reconstructing state mixtures from diffraction measurements
Pierre Thibault, Andreas Menzel · Nature · 2013 · 662 citations
Coherent lensless X-ray imaging
Henry N. Chapman, K. Nugent · Nature Photonics · 2010 · 590 citations · Full text