SLEEP Advances · 2023 · 22 citations · 34 references
NursingBiostatisticsPhysical ActivitySleep Disorders In Older AdultsSleep MedicineSleep AssessmentSleep DisturbanceSleep HealthSleep PhysiologySleep Signal AnalysisSleep-related FactorsIntraclass CorrelationLinear RegressionMonitoring Sleep DurationOpen-source Software DevelopmentPolysomnography AnalysisSleep Duration VariabilitySleep Quality AssessmentSleep Time
Abstract Comparisons of actigraphy findings between studies are challenging given differences between brand-specific algorithms. This issue may be minimized by using open-source algorithms. However, the accuracy of actigraphy-derived sleep parameters processed in open-source software needs to be assessed against polysomnography (PSG). Middle-aged adults from the Raine Study (n = 835; F 58%; Age 56.7 ± 5.6 years) completed one night of in-laboratory PSG and concurrent actigraphy (GT3X+ ActiGraph). Actigraphic measures of total sleep time (TST) were analyzed and processed using the open-source R-package GENEActiv and GENEA data in R (GGIR) with and without a sleep diary and additionally processed using proprietary software, ActiLife, for comparison. Bias and agreement (intraclass correlation coefficient) between actigraphy and PSG were examined. Common PSG and sleep health variables associated with the discrepancy between actigraphy, and PSG TST were examined using linear regression. Actigraphy, assessed in GGIR, with and without a sleep diary overestimated PSG TST by (mean ± SD) 31.0 ± 50.0 and 26.4 ± 69.0 minutes, respectively. This overestimation was greater (46.8 ± 50.4 minutes) when actigraphy was analyzed in ActiLife. Agreement between actigraphy and PSG TST was poor (ICC = 0.27–0.44) across all three methods of actigraphy analysis. Longer sleep onset latency and longer wakefulness after sleep onset were associated with overestimation of PSG TST. Open-source processing of actigraphy in a middle-aged community population, agreed poorly with PSG and, on average, overestimated TST. TST overestimation increased with increasing wakefulness overnight. Processing of actigraphy without a diary in GGIR was comparable to when a sleep diary was used and comparable to actigraphy processed with proprietary algorithms in ActiLife.
34
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Murray W. Johns · SLEEP · 1991 · 17.2K citations · Full text
Medicine, Neurology, Psychometrics +16
Richard B. Berry, Rohit Budhiraja, Daniel J. Gottlieb et al. · Journal of Clinical Sleep Medicine · 2012 · 5.2K citations · Full text
Automatic Sleep/Wake Identification From Wrist Activity
Roger J. Cole, Daniel F. Kripke, William Gruen et al. · SLEEP · 1992 · 1.9K citations · Full text