Clinical Oral Investigations · 2023 · 24 citations · 32 references
DentistryMaxillofacial SurgeryOral SurgeryImplant SurgeryMaxillofacial ImagingSurgical OrthodonticsImplant Position VerificationImplant Treatment PlanningMaxillary OsteotomyOcclusal Splint TherapyOrthognathic SurgeryOrthognathic Treatment PlanningImplant Positioning AccuracyPatient-specific Surgical SplintsPostoperative Position VerificationPreoperative Surgical Planning ImagingSurgical Outcome AssessmentSurgical Outcome EvaluationSurgical PlanningThree-dimensional Implant Positioning
OBJECTIVE: To determine the accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. MATERIAL AND METHODS: A retrospective analysis of 28 patients that underwent virtually planned orthognathic surgery with maxillary Le Fort I osteotomy either using VSP-generated splints (n = 13) or patient-specific implants (PSI) (n = 15) was conducted. The accuracy and surgical outcome of both techniques were compared by superimposing preoperative surgical planning with postoperative CT scans and measurement of translational and rotational deviation for each patient. RESULTS: The 3D global geometric deviation between the planned position and the postoperative outcome was 0.60 mm (95%-CI 0.46-0.74, range 0.32-1.11 mm) for patients with PSI and 0.86 mm (95%-CI 0.44-1.28, range 0.09-2.60 mm) for patients with surgical splints. Postoperative differences for absolute and signed single linear deviations between planned and postoperative position were a little higher regarding the x-axis and pitch but lower regarding the y- and z-axis as well as yaw and roll for PSI compared to surgical splints. There were no significant differences regarding global geometric deviation, absolute and signed linear deviations in the x-, y-, and z-axis, and rotations (yaw, pitch, and roll) between both groups. CONCLUSIONS: Regarding accuracy for positioning of maxillary segments after Le Fort I osteotomy in orthognathic surgery patient-specific implants and surgical splints provide equivalent high accuracy. CLINICAL RELEVANCE: Patient-specific implants for maxillary positioning and fixation facilitate the concept of splintless orthognathic surgery and can be reliably used in clinical routines.
32
Samir Aboul-Hosn Centenero, Federico Hernández‐Alfaro · Journal of Cranio-Maxillofacial Surgery · 2011 · 313 citations
James J. Xia, Jaime Gateño, John F. Teichgraeber et al. · Journal of Oral and Maxillofacial Surgery · 2007 · 248 citations