Electrochemical Investigations of Dopamine at Chemically Modified Losartan Carbon Paste Electrode: A Cyclic Voltammetric Study

M.T. Shreenivas, B.E. Kumara Swamy, Umesh Chandra, S. Sharath Shankar, J. G. Manjunatha, B.S. Sherigara

International Journal of Electrochemical Science · 2010 · 16 citations · 14 references

DOIFull text

Open access

Concepts

Abstract

A carbon paste electrode modified by Losartan was used for detection of dopamine (DA). The modified electrode exhibited strong promoting effect and stability towards the electrochemical oxidation of DA in phosphate buffer solution (PBS) at pH 7.0. The effects of scan rate, concentration, and pH have been studied. The detection limit of the modified carbon paste electrode was 1 x 10-7 M for dopamine. The preparation of the modified electrode is very easy and renewed by simple polishing gave very good reproducibility, high stability in its voltammetric response and low detection limit for DA.

References