IEEE Transactions on Biomedical Circuits and Systems · 2023 · 12 citations · 37 references
EngineeringBioengineeringBiomedical EngineeringBioinstrumentationBiomedical Signal ProcessingSensorsBiomedical InstrumentationMagnetic Resonance Signal FormationMedical Imaging InstrumentationMedical InstrumentationPoint-of-care Diagnostic DevicesRelaxation MechanismsAutomatic Frequency ControlMagnetic Field StrengthMagnetic Relaxation MeasurementsMagnetic Resonance Imaging InstrumentationNuclear Magnetic Resonance RelaxometryPower Amplifier ControlPower Amplifier Stages
In this article, we present a portable NMR relaxometry system optimized for the point-of-care analysis of body liquids such as blood. The presented system is centered on an NMR-on-a-chip transceiver ASIC, a reference frequency generator with arbitrary phase control, and a custom-designed miniaturized NMR magnet with a field strength of 0.29 T and a total weight of 330 g. The NMR-ASIC co-integrates a low-IF receiver, a power amplifier, and a PLL-based frequency synthesizer on a total chip area of 1100 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\boldsymbol{\times }$</tex-math></inline-formula> 900 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mu$</tex-math></inline-formula> m <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\boldsymbol{^{2}}$</tex-math></inline-formula> . The arbitrary reference frequency generator enables the use of conventional CPMG and inversion sequences, as well as modified water-suppression sequences. Moreover, it is used to implement an automatic frequency lock to correct temperature-induced magnetic field drifts. Proof-of-concept measurements on NMR phantoms and human blood samples show an excellent concentration sensitivity of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">v</i> <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\boldsymbol{_\text{c,min}}$</tex-math></inline-formula> = 2.2 mM/ <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\boldsymbol{\sqrt{\text{Hz}}}$</tex-math></inline-formula> . This very good performance renders the presented system an ideal candidate for the future NMR-based point-of-care detection of biomarkers such as the blood glucose concentration.
37
NMR spectroscopy up to 35.2 T using a series-connected hybrid magnet
Zhehong Gan, Ivan Hung, Xiao-Ling Wang et al. · Journal of Magnetic Resonance · 2017 · 202 citations · Full text