Medicine and Pharmacy Reports · 2023 · 17 citations · 18 references
DentistryDental Materials ScienceProsthodonticsDental MaterialsProstheticsProsthodontic MaterialsComputer-aided Design In ProsthodonticsComputer-aided Manufacturing In ProsthodonticsDigital Fixed ProsthodonticsMaxillofacial Prosthetics3D-printed Provisional RestorationsComputer-aided Manufacturing Marginal FitMarginal Fit Of AbutmentsProsthesis Marginal AdaptationProsthetic Marginal FitProvisional Fixed ProsthesesProvisional Prosthesis FabricationThree-dimensional Printing Of Prostheses
Introduction: Provisional dental prostheses are used as interim restorations to help patients perform oral functions between the time of tooth preparation and the placement of the final restoration. A provisional dental prosthesis should protect the abutment from pulpal and gingival aggressions, adapt correctly to keep healthy gingival tissues, be durable, and have a low price. The purpose of this in vitro study was to compare the marginal adaptation of different types of provisional fixed dental prostheses (PFDP), fabricated using 3D printing technology versus the milling (computer-aided manufacturing [CAM]) technique. Method: Two resin teeth (second premolar and second molar) on a typodont were prepared for three-unit provisional fixed dental prostheses. Thirty models were 3D-printed after a digital model was created using an intraoral scanner. Then, 30 provisional fixed dental prostheses (PFDPs) were made from a variety of materials using a digital design of a 3-unit PFDP and STL files delivered to a milling machine and a 3D printer, respectively. Ten PFDP were milled (CAM), and two sets of ten each, were fabricated with 3D printing technology (stereolithography), using two different materials. All restorations were analyzed under a microscope, and marginal gap was then measured using the software Image J. Results: The milled group presented the best marginal gap values (ranging from 86 to 108 μm) and a median value of 93 μm, followed by GC group with (110-251 μm) with a median value of 205 μm and the PR group with median value of 316.5 μm. Conclusion: According to the findings of this in vitro study, the milling (CAM) technique and SLA technology provides acceptable marginal fit values to fabricate provisional fixed partial dentures.
18
NIH Image to ImageJ: 25 years of image analysis
Caroline A Schneider, Wayne Rasband, Kevin W. Eliceiri · Nature Methods · 2012 · 65.2K citations
The estimation of cement film thickness by an in vivo technique
J W McLean, Fraunhofer von · BDJ · 1971 · 1.4K citations
Medical Applications for 3D Printing: Current and Projected Uses.
C Lee Ventola · PubMed · 2014 · 927 citations
Ji Suk Shim, Jong‐Eun Kim, Sang Hoon Jeong et al. · Journal of Prosthetic Dentistry · 2019 · 418 citations
Engineering, Manufacturing Engineering, Additive Manufacturing +12