IEEE Transactions on Dielectrics and Electrical Insulation · 2023 · 17 citations · 12 references
EngineeringElectrical EngineeringElectric MachinesFinite Element AnalysisMachine DesignInsulation SystemsMachine WindingsPhysical ParameterizationFinite Element Analysis Of MachinesForm Wound CoilsInsulation DesignInsulation Systems For WindingsInverter DesignMachine ModelMachine Winding InsulationPartial Discharge
The Schumann inception criterion was used to predict the partial discharge inception voltage (PDIV) of insulation models representing both wire wound and form wound (hairpin) low voltage machines. It was found that the fitting parameter <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${K}$ </tex-math></inline-formula> (the logarithm of the critical number of electrons that define the transition from Townsend to streamer discharge) is almost independent of material parameters when dealing with a given type of insulation (e.g., turn-to-turn using round conductors or flat conductors). These numbers can be fed to software for finite element analysis to provide a worst-case estimate of the PDIV.
12