IEEE Transactions on Electron Devices · 2023 · 15 citations · 27 references
Natural SciencesMaterials EngineeringMaterials ScienceElectronic MaterialsRadiation DosimetrySemiconductor DevicesRadiographic ImagingX-ray DetectionX-ray OpticsX-ray SpectroscopyIndustrial X-ray InspectionLuminous TransmittanceOptical TransmittanceRadiation IntensityRadiation TransmittanceX-ray Imaging PhysicsX-ray Imaging SystemsX-ray Spectra
X-ray sources have important applications in medical diagnosis, industrial inspection, etc. Transparent X-ray source has not been reported before, which enables the applications such as simultaneous imaging using X-ray and visible light. In this article, a fully vacuum-encapsulated transparent flat-panel X-ray source was prepared by using ZnO nanowires cold cathode and indium-tin-oxide (ITO) transmission anode. The effect of thicknesses of ITO film on X-ray radiation intensity was studied. A radiation dose rate of 6.85 mGy/s measured at 5 cm in front of the flat-panel X-ray source (FPXS) under 48-kV anode voltage and an optical transmittance of 72.63% at 550-nm light were achieved. X-ray spectra show the indium is the main element to generate the X-ray. By adopting the device in an X-ray and visible light dual-functional inspection set-up, the X-ray and visible light imaging of objects were demonstrated simultaneously.
27
Thermionic Emission, Field Emission, and the Transition Region
E. L. Murphy, R. H. Good · Physical Review · 1956 · 1.5K citations
Space-Charge Effects in Field Emission
J. P. Barbour, W. W. Dolan, J. K. Trolan et al. · Physical Review · 1953 · 273 citations
Akihiro Haga, S. Senda, Yusuke Sakai et al. · Applied Physics Letters · 2004 · 91 citations