Journal of the American Society for Mass Spectrometry · 2023 · 17 citations · 12 references
PharmacyBiochemistryAnalytical ChemistryMass Spectrometric AnalysisProteomicsAccurate Mass MeasurementLipidomicsMass Spectrometric ImagingMass SpectrometryMass Spectrometry Data AnalysisPeptide AnalysisData ProcessingHigh-resolution Mass AnalysisImaging Mass Spectrometry Data ProcessingLipid AnnotationMass Spectrometry Quality ControlMeasurement AccuracyOrbitrap Mass SpectrometrySensitivity
The collection of profile data is standard practice within the field of mass spectrometry (MS). However, profile data collection often results in large data files that require extensive processing times, especially in mass spectrometry imaging (MSI) studies where thousands of high-resolution scans are recorded. Natively collecting centroid MS data is an alternative that effectively reduces both the resulting file size and the data processing time. Herein, high-resolution accurate mass (HRAM) Orbitrap MSI data on mouse liver tissue sections without automatic gain control (AGC) were natively collected in both profile and centroid modes and compared based on the file size and processing time. Additionally, centroid data were evaluated against the profile data with regard to the spectra integrity, mass measurement accuracy (MMA), and the number of lipid annotations to ensure that centroid data did not compromise the data quality. For both native and postacquisition centroided data, the variation in mass measurement accuracy decreased relative to the profile data collection. Furthermore, centroid data collection increased the number of METASPACE database annotations indicating higher sensitivity and greater accuracy for lipid annotation compared to native profile data collection. Profile MSI data was shown to have a higher likelihood of false positive identifications due to an increased number of data points on either side of the peaks, whereas the same trend was not observed in data collected in native centroid data collection. This publication explores and explains the importance in properly centroiding MSI data, either natively or by adequate centroiding methods, to obtain the most accurate information and come to the best conclusions. These data support that natively collecting centroid data significantly improves MMA to sub-ppm levels without AGC and reduces false positive annotations.
12
LIPID MAPS online tools for lipid research
Eoin Fahy, Manish Sud, David Cotter et al. · Nucleic Acids Research · 2007 · 932 citations · Full text
FDR-controlled metabolite annotation for high-resolution imaging mass spectrometry
Andrew Palmer, Prasad Phapale, Ilya Chernyavsky et al. · Nature Methods · 2016 · 520 citations · Full text
Mark T. Bokhart, Milad Nazari, Kenneth P. Garrard et al. · Journal of the American Society for Mass Spectrometry · 2017 · 266 citations · Full text
Jason S. Sampson, Kermit K. Murray, David C. Muddiman · Journal of the American Society for Mass Spectrometry · 2008 · 109 citations