Journal of Biomedical Optics · 2023 · 10 citations · 31 references
Natural SciencesBiomedical EngineeringPhysicsBiophotonicsPhotonicsSpectroscopyLight-tissue InteractionOptical BiopsyOptical DiagnosticsOptical SpectroscopyTime-resolved SpectroscopyTissue Optical PropertiesComputational PhantomsDepth-resolved AbsorptionDiffuse Optical SpectroscopyScatteringSolid PhantomsSource-detector Spacing EffectsTissue Light Penetration DepthWater Phantom Measurements
Significance: optical biopsies, endoscopic interventions, and local monitoring of therapy. Different from other photonics approaches, time-domain diffuse optical spectroscopy (TD-DOS) can probe the tissue at a few cm distance from the fiber tip and disentangle absorption from the scattering properties. Nevertheless, the signal detected at a short distance from the source is strongly dominated by the photons arriving early at the detector, thus hampering the possibility of resolving late photons, which are rich in information about depth and absorption. Aim: To fully benefit from the null-distance approach, a detector with an extremely high dynamic range is required to effectively collect the late photons; the goal of our paper is to test its feasibility to perform TD-DOS measurements at null source-detector separations (NSDS). Approach: by exploiting the high dynamic range and temporal resolution of the SNSPD to extract late arriving, deep-traveling photons from the burst of early photons. Results: This approach was demonstrated both on Monte Carlo simulations and on phantom measurements, achieving an accuracy in the retrieval of the water spectrum of better than 15%, spanning almost two decades of absorption change in the 700- to 1100-nm range. Additionally, we show that, for interstitial measurements at null source-detector distance, the scattering coefficient has a negligible effect on late photons, easing the retrieval of the absorption coefficient. Conclusions: Utilizing the SNSPD, broadband TD-DOS measurements were performed to successfully retrieve the absorption spectra of the liquid phantoms. Although the SNSPD has certain drawbacks for use in a clinical system, it is an emerging field with research progressing rapidly, and this makes the SNSPD a viable option and a good solution for future research in needle guided time-domain interstitial fiber spectroscopy.
31
Diffuse optics for tissue monitoring and tomography
Turgut Durduran, Regine Choe, Wesley B. Baker et al. · Reports on Progress in Physics · 2010 · 1.2K citations
Richard Doornbos, Rossano Lang, Maurice C. G. Aalders et al. · Physics in Medicine and Biology · 1999 · 380 citations
Performance assessment of photon migration instruments: the MEDPHOT protocol
Antonio Pifferi, Alessandro Torricelli, Andrea Bassi et al. · Applied Optics · 2005 · 241 citations · Full text