IEEE Sensors Journal · 2022 · 12 citations · 26 references
EngineeringBiomedical EngineeringComputational Fluid DynamicsPhotonicsSensorsFlow MeasurementFlow MetrologyFlow SensorsInterferometryOptical MetrologyOptical SensorsFiber-optic Flow SensorsFlow Measurement SystemsFlow Rate DependenceFlow Rate MonitoringFlow Velocity MeasurementsInterferometric MeasurementInterferometric SensorsSensor Sensitivity
A novel scheme for the measurement of an ultralow flow rate based on a fiber Fabry–Perot interferometer (FPI) and sensitivity-enhanced Vernier effect is proposed. The impact of water at different flow rates varies the cavity length of the sensor, resulting in a change of the free spectrum range (FSR) of the interferometric spectrum. The theoretical relation between the FSR and flow rate has been established by numerical simulation. The sensitivity can be further enhanced via the Vernier effect with a virtual reference cell and experimentally verified in the flow rate range of 0– <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$80\,\mu \text{m}$ </tex-math></inline-formula> /s. The proposed interferometric sensor with modified Vernier effect is used for ultralow flow rate measurements for the first time, which shows the potential for applications in microfluidic technology and biochemical reaction.
26
Optical Harmonic Vernier Effect: A New Tool for High Performance Interferometric Fiber Sensors
Sensors · 2019 · 176 citations · Full text
Engineering, Physics, Optics +16
Microfluidic flowmeter based on micro “hot-wire” sandwiched Fabry-Perot interferometer
Ying Li, Guofeng Yan, Liang Zhang et al. · Optics Express · 2015 · 71 citations · Full text