Journal of Magnetic Resonance Imaging · 2022 · 16 citations · 29 references
MedicineCardiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiac AssessmentCardiac ImagingCardiovascular ImagingEchocardiographic Hemodynamic AssessmentLeft Ventricular Function AssessmentMagnetic Resonance Imaging4D Flow Magnetic Resonance ImagingCardiac Flow QuantificationDiastolic Function EvaluationEchocardiographic QuantificationFour-dimensional Flow ImagingMagnetic Resonance Flow ImagingMagnetic Resonance Flow QuantificationVentricular Diastolic Function
BACKGROUND: Four-dimensional (4D) flow MRI allows for the quantification of complex flow patterns; however, its clinical use is limited by its inherently long acquisition time. Compressed sensing (CS) is an acceleration technique that provides substantial reduction in acquisition time. PURPOSE: To compare intracardiac flow measurements between conventional and CS-based highly accelerated 4D flow acquisitions. STUDY TYPE: Prospective. SUBJECTS: Fifty healthy volunteers (28.0 ± 7.1 years, 24 males). FIELD STRENGTH/SEQUENCE: Whole heart time-resolved 3D gradient echo with three-directional velocity encoding (4D flow) with conventional parallel imaging (factor 3) as well as CS (factor 7.7) acceleration at 3 T. ASSESSMENT: 4D flow MRI data were postprocessed by applying a valve tracking algorithm. Acquisition times, flow volumes (mL/cycle) and diastolic function parameters (ratio of early to late diastolic left ventricular peak velocities [E/A] and ratio of early mitral inflow velocity to mitral annular early diastolic velocity [E/e']) were quantified by two readers. STATISTICAL TESTS: Paired-samples t-test and Wilcoxon rank sum test to compare measurements. Pearson correlation coefficient (r), Bland-Altman-analysis (BA) and intraclass correlation coefficient (ICC) to evaluate agreement between techniques and readers. A P value < 0.05 was considered statistically significant. RESULTS: A significant improvement in acquisition time was observed using CS vs. conventional accelerated acquisition (6.7 ± 1.3 vs. 12.0 ± 1.3 min). Net forward flow measurements for all valves showed good correlation (r > 0.81) and agreement (ICCs > 0.89) between conventional and CS acceleration, with 3.3%-8.3% underestimation by the CS technique. Evaluation of diastolic function showed 3.2%-17.6% error: E/A 2.2 [1.9-2.4] (conventional) vs. 2.3 [2.0-2.6] (CS), BA bias 0.08 [-0.81-0.96], ICC 0.82; and E/e' 4.6 [3.9-5.4] (conventional) vs. 3.8 [3.4-4.3] (CS), BA bias -0.90 [-2.31-0.50], ICC 0.89. DATA CONCLUSION: Analysis of intracardiac flow patterns and evaluation of diastolic function using a highly accelerated 4D flow sequence prototype is feasible, but it shows underestimation of flow measurements by approximately 10%. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.
29
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text
Li Feng, Robert Grimm, Kai Tobias Block et al. · Magnetic Resonance in Medicine · 2013 · 716 citations · Full text