Magnetic Resonance in Medicine · 2013 · 716 citations · 37 references
EngineeringBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyImage ReconstructionMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingMedical Imaging InstrumentationCompressed SensingCompressed Sensing Magnetic Resonance ImagingDynamic ImagingDynamic Magnetic Resonance Imaging ReconstructionIterative ReconstructionK-space ReconstructionParallel ImagingUndersampled Magnetic Resonance Imaging Reconstruction
The study develops iGRASP, a fast, flexible free‑breathing dynamic volumetric MRI technique that integrates compressed sensing, parallel imaging, and golden‑angle radial sampling. iGRASP acquires continuous golden‑angle radial k‑space data, groups spokes into temporal frames, and reconstructs undersampled series with an iterative multicoil total‑variation constrained algorithm using coil‑sensitivity profiles derived from time‑averaged data. iGRASP delivers higher acceleration than parallel imaging or coil‑by‑coil compressed sensing alone, enabling high‑spatial‑ and temporal‑resolution dynamic volumetric imaging in abdominal, breast, and neck studies while improving motion robustness. Published in Magn Reson Med 72:707–717 (2014); © 2013 Wiley Periodicals, Inc.
Purpose To develop a fast and flexible free‐breathing dynamic volumetric MRI technique, iterative Golden‐angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden‐angle radial sampling. Methods Radial k‐space data are acquired continuously using the golden‐angle scheme and sorted into time series by grouping an arbitrary number of consecutive spokes into temporal frames. An iterative reconstruction procedure is then performed on the undersampled time series where joint multicoil sparsity is enforced by applying a total‐variation constraint along the temporal dimension. Required coil‐sensitivity profiles are obtained from the time‐averaged data. Results iGRASP achieved higher acceleration capability than either parallel imaging or coil‐by‐coil compressed sensing alone. It enabled dynamic volumetric imaging with high spatial and temporal resolution for various clinical applications, including free‐breathing dynamic contrast‐enhanced imaging in the abdomen of both adult and pediatric patients, and in the breast and neck of adult patients. Conclusion The high performance and flexibility provided by iGRASP can improve clinical studies that require robustness to motion and simultaneous high spatial and temporal resolution. Magn Reson Med 72:707–717, 2014. © 2013 Wiley Periodicals, Inc.
37
David L. Donoho · IEEE Transactions on Information Theory · 2006 · 23.1K citations
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text