Head & Neck · 2022 · 27 citations · 18 references
MedicineSurgery3D ModelingBiomedical ImagingSurgical PathologyMargin AssessmentMedical ImagingSpecimen DocumentationThree-dimensional ReconstructionTumor MarginsClose Margin AssessmentMargin Status EvaluationMargin Status ReportingOncologic Margin AssessmentPositive Margin AssessmentResection Margin MappingSurgical Site DocumentationTumor Margin Status
BACKGROUND: Numerous challenges exist in determining surgical margin status. Communication between surgeons and pathologists is crucial for specimen orientation and accurate margin assessment. METHODS: A prospective study to determine feasibility of incorporating three-dimensional (3D) scanning into surgical pathology workflow was performed. A structured-light 3D scanner captured the photorealistic surface topography of fresh surgical specimens. Computer-aided design (CAD) software was used to document sites of margin sampling and sectioning. Surveys were distributed among faculty and staff stakeholders to assess feasibility. RESULTS: A series of 40 cases were 3D-scanned. Median image acquisition time was 8 min. The majority of respondents agreed that the experimental 3D system helped achieve clearer communication. 3D specimen maps assisted in the communication of a focally positive or close margin in 4 of 17 cases. CONCLUSIONS: Routine 3D scanning and specimen mapping is feasible and represents an innovative approach to intraoperative and final pathology documentation, margin analysis, and surgeon-pathologist communication.
18
Positive Surgical Margins in the 10 Most Common Solid Cancers
Ryan K. Orosco, Viridiana J. Tapia, Joseph A. Califano et al. · Scientific Reports · 2018 · 278 citations · Full text