IEEE Journal of Solid-State Circuits · 2022 · 16 citations · 26 references
EngineeringChemical EngineeringElectrical EngineeringMicroelectromechanical SystemsMicroelectronicsSensorsChemical SensorsElectrical SensorsGas SensorsMems SensorsMicroelectromechanical SensorsSensor MaterialsAnalog-to-digital Converter DesignBias Circuit DesignEnergy-efficient Digital CircuitsGas SensingGas Sensor SensitivitySemiconductor Gas SensorsSensor CharacterizationSensor Technology
This article presents an energy-efficient resistor-to-digital converter (RDC) intended for use in a gas sensor system to detect harmful benzene, toluene, ethyl-benzene, and xylene (BTEX) compounds. The sensor is based on a resistive micro-electromechanical systems (MEMS) sensor, whose selectivity is tuned by different heating levels of micro-heater, allowing a single sensor to detect multiple gases. To achieve both high resolution and energy efficiency, the sensor’s output current is digitized by a continuous-time (CT) delta–sigma ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta \Sigma $ </tex-math></inline-formula> ) RDC. It combines the bias circuit for the sensor and the RDC’s first integrator, and then, its charge balancing between the sensor resistor and the 16-level feedback resistive digital-to-analog converter (RDAC) allows the use of a low bias current. Fabricated in the 110-nm CMOS process, the prototype RDC achieves an 18.8-bit resolution in a resistance range from 20 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text{k}\Omega $ </tex-math></inline-formula> to 500 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text{k}\Omega $ </tex-math></inline-formula> . The sensor system is validated through a transient response of BTEX and a principal component analysis (PCA). It achieves 0.1-to-5-ppb gas resolution in the BTEX concentration range of 9 ppm with a measurement time of 0.5 ms, while consuming 95 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{W}$ </tex-math></inline-formula> from a 1.5-V supply. This corresponds to an energy consumption of 47.5 nJ.
26
Source profiles of volatile organic compounds (VOCs) measured in China: Part I
Ying Liu, Min Shao, Linlin Fu et al. · Atmospheric Environment · 2008 · 895 citations
Volatile Organic Compounds, Indoor Air Quality and Health
Lars Mølhave · Indoor Air · 1991 · 313 citations