IEEE Transactions on Transportation Electrification · 2022 · 30 citations · 18 references
EngineeringAerospace EngineeringSystems EngineeringFault ToleranceFault-tolerant SystemsPropulsionDevice ReliabilityElectric Motor Drive SystemsFailure CriteriaPower System ReliabilityReliability ModelingReliable System DesignAircraft ReliabilityElectrical System ReliabilityFault-tolerant Drive SystemsFault-tolerant PropulsionMotor Drive Reliability AnalysisMotor Drive SystemsPropulsion System ReliabilityReliability Analysis Of Power Electronics
Electrified urban air mobility (UAM) aircraft requires catastrophic failure rates for their propulsion systems that are lower than <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{-9}$ </tex-math></inline-formula> failures per flight hour. Electric machines and drives have been identified as limiting propulsion subsystems with failure rates in the range of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{-5}$ </tex-math></inline-formula> – <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{-6}$ </tex-math></inline-formula> failures/h. Fault-tolerant (FT) machine drives offer a promising approach to improve reliability using existing technology. An FT integrated modular motor drive (IMMD) design is proposed for a quadrotor UAM application, and its estimated reliability is studied using Markov chain analysis. Quantitative examples show that raising the repair rate for the motor drive modules significantly reduces the IMMD’s catastrophic failure rate. However, the lower bound on its failure rate with high repair rates is determined by its single-point failure (SPF) rate (e.g., motor bearings), highlighting the importance of aggressively suppressing as many of the IMMD’s SPFs as possible. Markov chain analysis shows that SPF suppression can result in major reductions in the IMMD catastrophic failure rate by factors exceeding <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{3}$ </tex-math></inline-formula> as the SPF rate is driven toward its ideal limit value of zero.
18
Seungdeog Choi, Moinul Shahidul Haque, Md Tawhid Bin Tarek et al. · IEEE Transactions on Transportation Electrification · 2018 · 188 citations
Engineering, Electrical Engineering, Condition Assessment +16
Electric/Hybrid-Electric Aircraft Propulsion Systems
Patrick Wheeler, Samith Sirimanna, Serhiy Bozhko et al. · Proceedings of the IEEE · 2021 · 167 citations
Engineering, Aerospace Engineering, Electrical Engineering +17