Publication | Open Access
Distribution of Liquid Mass in Transient Sprays Measured Using Laser-Plasma-Driven X-Ray Tomography
16
Citations
36
References
2022
Year
EngineeringMicroscopyLiquid-liquid FlowFluid MechanicsLaser Plasma PhysicLarge VolumeX-ray ImagingInstrumentationSpatial ResolutionRadiologyHealth SciencesPhysicsLiquid Mass DistributionMultiphase FlowX-ray Free-electron LaserLaser-induced BreakdownPlasma ApplicationX-ray OpticLiquid Mass
We report, the use of laser-plasma-driven x rays to reveal the three-dimensional (3D) structure of a highly atomizing water spray. Soft x rays approximately 5 keV are generated by means of a laser-plasma accelerator. Transmission radiography measurements are performed at different angles, by rotating a multihole injector. Using computer tomography, the local liquid volume distribution and its spatial variation are retrieved in 3D, showing up to 55% liquid fraction at the nozzle outlet, which decreases to below 7% within only 1 mm. The resolution of the liquid volume fraction is 0.5% while the spatial resolution of the radiographic images is $11.5\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{m}$. The x-ray source used here provides successful measurements of liquid mass distribution over a relatively large volume and is very promising for the analysis of a variety of challenging transient spray systems, e.g., the injection of liquid synthetic and biofuels used for future clean-combustion applications.