Analytical Chemistry · 2022 · 19 citations · 37 references
MedicineOncologyPathologyBiomedical ImagingDiagnostic ImagingMass Spectrometric AnalysisBioanalytical Method ValidationMass Spectrometric ImagingMass SpectrometryMass Spectrometry Data AnalysisTumor CharacterizationTumor ImagingLung Squamous Cell CarcinomaMatrix-assisted Laser Desorption ImagingMatrix-assisted Laser Desorption Ionization Time-of-flight Mass SpectrometryMatrix-assisted Laser Desorption/ionizationMatrix-assisted Laser Desorption/ionization ImagingMatrix-assisted Laser Desorption/ionization Time-of-flight Mass SpectrometryTissue ClassificationTissue Phenotyping
Many studies have demonstrated that tissue phenotyping (tissue typing) based on mass spectrometric imaging data is possible; however, comprehensive studies assessing variation and classifier transferability are largely lacking. This study evaluated the generalization of tissue classification based on Matrix Assisted Laser Desorption/Ionization (MALDI) mass spectrometric imaging (MSI) across measurements performed at different sites. Sections of a tissue microarray (TMA) consisting of different formalin-fixed and paraffin-embedded (FFPE) human tissue samples from different tumor entities (leiomyoma, seminoma, mantle cell lymphoma, melanoma, breast cancer, and squamous cell carcinoma of the lung) were prepared and measured by MALDI-MSI at different sites using a standard protocol (SOP). Technical variation was deliberately introduced on two separate measurements via a different sample preparation protocol and a MALDI Time of Flight mass spectrometer that was not tuned to optimal performance. Using standard data preprocessing, a classification accuracy of 91.4% per pixel was achieved for intrasite classifications. When applying a leave-one-site-out cross-validation strategy, accuracy per pixel over sites was 78.6% for the SOP-compliant data sets and as low as 36.1% for the mistuned instrument data set. Data preprocessing designed to remove technical variation while retaining biological information substantially increased classification accuracy for all data sets with SOP-compliant data sets improved to 94.3%. In particular, classification accuracy of the mistuned instrument data set improved to 81.3% and from 67.0% to 87.8% per pixel for the non-SOP-compliant data set. We demonstrate that MALDI-MSI-based tissue classification is possible across sites when applying histological annotation and an optimized data preprocessing pipeline to improve generalization of classifications over technical variation and increasing overall robustness.
37
A test metric for assessing single-cell RNA-seq batch correction
Maren Büttner, Zhichao Miao, F. Alexander Wolf et al. · Nature Methods · 2018 · 539 citations · Full text
HistoQC: An Open-Source Quality Control Tool for Digital Pathology Slides
Andrew Janowczyk, Ren Zuo, Hannah Gilmore et al. · JCO Clinical Cancer Informatics · 2019 · 361 citations