Sensors · 2022 · 28 citations · 55 references
EngineeringBiomedical EngineeringRadiologyDiagnostic ImagingUltrasonographyUltrasoundDiagnostic UltrasonographyMedical ImagingNoiseNoise ReductionPhotoacoustic ImagingUltrasonicsConvolutional Neural NetworksElectromagnetic InterferenceElectromagnetic Interference ReductionElectromagnetic Interference SuppressionNoise Reduction AlgorithmsPhotoacoustic EndoscopyPhotoacoustic Signal ProcessingSignal-to-noise Ratio
Despite all the expectations for photoacoustic endoscopy (PAE), there are still several technical issues that must be resolved before the technique can be successfully translated into clinics. Among these, electromagnetic interference (EMI) noise, in addition to the limited signal-to-noise ratio (SNR), have hindered the rapid development of related technologies. Unlike endoscopic ultrasound, in which the SNR can be increased by simply applying a higher pulsing voltage, there is a fundamental limitation in leveraging the SNR of PAE signals because they are mostly determined by the optical pulse energy applied, which must be within the safety limits. Moreover, a typical PAE hardware situation requires a wide separation between the ultrasonic sensor and the amplifier, meaning that it is not easy to build an ideal PAE system that would be unaffected by EMI noise. With the intention of expediting the progress of related research, in this study, we investigated the feasibility of deep-learning-based EMI noise removal involved in PAE image processing. In particular, we selected four fully convolutional neural network architectures, U-Net, Segnet, FCN-16s, and FCN-8s, and observed that a modified U-Net architecture outperformed the other architectures in the EMI noise removal. Classical filter methods were also compared to confirm the superiority of the deep-learning-based approach. Still, it was by the U-Net architecture that we were able to successfully produce a denoised 3D vasculature map that could even depict the mesh-like capillary networks distributed in the wall of a rat colorectum. As the development of a low-cost laser diode or LED-based photoacoustic tomography (PAT) system is now emerging as one of the important topics in PAT, we expect that the presented AI strategy for the removal of EMI noise could be broadly applicable to many areas of PAT, in which the ability to apply a hardware-based prevention method is limited and thus EMI noise appears more prominently due to poor SNR.
55
Image quality assessment: from error visibility to structural similarity
Zhou Wang, Alan C. Bovik, Hamid R. Sheikh et al. · IEEE Transactions on Image Processing · 2004 · 56K citations
Beyond a Gaussian Denoiser: Residual Learning of Deep CNN for Image Denoising
Kai Zhang, Wangmeng Zuo, Yunjin Chen et al. · IEEE Transactions on Image Processing · 2017 · 8.8K citations · Full text
Biomedical photoacoustic imaging
Paul C. Beard · Interface Focus · 2011 · 2.2K citations