Electronic physician · 2016 · 33 citations · 19 references
EngineeringEnvironmental EngineeringIndustrial MicrobiologyWastewater TreatmentWater TreatmentDrug RemovalPathogen RemovalChemical Oxygen DemandConcentrationContact Time EffectsFood Chain ContaminationMicrobial RemovalPharmaceutical RemovalResponse Surface TestingSolution Contact Time
Introduction: Penicillin G (PG) is used in a variety of infectious diseases, extensively. Generally, when antibiotics are introduced into the food chain, they pose a threat to the environment and can risk health outcomes. The aim of the present study was the removal of Penicillin G from an aqueous solution through an integrated system of UV/ZnO and UV/WO3 with Ultrasound pretreatment. Methods: In this descriptive-analytical work dealing with the removal of Penicillin G from an aqueous solution, four significant variables, contact time (60-120 min), Penicillin G concentration (50-150 mg/L), ZnO dose (200-400 mg/L), and WO3 dose (100-200 mg/L) were investigated. Experiments were performed in a Pyrex reactor (batch, 1 Lit) with an artificial UV 100-Watt medium pressure mercury lamp, coupled with ultrasound (100 W, 40 KHz) for PG pre-treatment. Chemical Oxygen Demand (COD) was selected to follow the performance of the photo-catalytic process and sonolysis. The experiments were based on a Central Composite Design (CCD) and analyzed by Response Surface Methodology (RSM). A mathematical model of the process was designed according to the proposed degradation scheme.
19
Degradation of selected pharmaceuticals in aqueous solution with UV and UV/H2O2
Yuan Fang, Chun Hu, Xuexiang Hu et al. · Water Research · 2009 · 355 citations
Pharmacy, Pharmaceutical Analysis, Pharmaceutical Technology +6