Journal of Nuclear Science and Technology · 1980 · 10 citations · 3 references
EngineeringChemical EngineeringSeparation ProcessesSeparation ScienceWater TreatmentGas SeparationGas-liquid SeparationDegradationHeavy Liquid SeparationIsotopic Exchange ProcessesSeparation Efficiency OptimizationSeparator PerformanceSeparator Performance ModelingTemperature OptimumWater Vapor Isotopic Composition
In order to study the separation characteristics for a pair of dual temperature multistage-type H2/H2O-exchange columns, each stage of which is composed of the scrubbing packed bed for the water/vapor isotopic exchange and the hydrophobic Pt catalyst bed for the vapor/hydrogen isotopic exchange, the authors tried to compose the finite difference equations considering the water/vapor isotopic exchange and the vapor/hydrogen isotopic exchange and then made it possible to calculate the D-content in the water, vapor and hydrogen at any point in a pair of dual temperature multistage-type H2/H2O-exchange columns by way of six variable—one order matrix equation derived from the six boundary conditions. Utilizing the results mentioned above, the authors tried a further study to get an optimum value of hydrogen/water molar flow ratio, number of stages in a cold column and a hot column, degradation ratio ((z w B -z- w F /z w B ) and specific volume (m3/kmol D2O-h) of a pair of dual temperature multistage-type H2/H2O-exchange columns, in an example case where the temperature in the cold and hot columns, the enrichment factor, the catalytic exchange efficiency and scrubbing efficiency were given at normal pressure.
3