Proceedings of SPE Annual Technical Conference and Exhibition · 1983 · 10 citations · 0 references
EngineeringEarth SciencesInstrumentationPetrophysicsWell TestingFlow MeasurementPermeability AnalysisPermeability CharacterizationPermeability EstimationPermeability EvaluationRelative PermeabilityCorrective Action MechanismsMultiphase PermeabilityMultiphase Relative PermeabilityPermeability MeasurementPermeability StudiesPhotodiode ArraysRelative Permeability AnalysisRelative Permeability Measurements
Multiphase Relative Permeability Measurements Using an Automated Centrifuge D.J. O'Meara, Jr.; D.J. O'Meara, Jr. Shell Development Co. Search for other works by this author on: This Site Google Scholar W.O. Lease W.O. Lease Shell Development Co. Search for other works by this author on: This Site Google Scholar Paper presented at the SPE Annual Technical Conference and Exhibition, San Francisco, California, October 1983. Paper Number: SPE-12128-MS https://doi.org/10.2118/12128-MS Published: October 05 1983 Cite View This Citation Add to Citation Manager Share Icon Share Twitter LinkedIn Get Permissions Search Site Citation O'Meara, D.J., and W.O. Lease. "Multiphase Relative Permeability Measurements Using an Automated Centrifuge." Paper presented at the SPE Annual Technical Conference and Exhibition, San Francisco, California, October 1983. doi: https://doi.org/10.2118/12128-MS Download citation file: Ris (Zotero) Reference Manager EasyBib Bookends Mendeley Papers EndNote RefWorks BibTex Search Dropdown Menu toolbar search search input Search input auto suggest filter your search All ContentAll ProceedingsSociety of Petroleum Engineers (SPE)SPE Annual Technical Conference and Exhibition Search Advanced Search AbstractThe automated centrifuge uses a linear photodiode array in conjunction with a microcomputer to image and identify liquids recovered from centrifuged rock samples. Compared to previous centrifuge measuring techniques this new systemObtains and analyzes production dataelectronically, thus requiring little human intervention.reduces inaccuracies in measurements allows for collecting initial data whenliquid levels are changing rapidly. provides for easy corrective action if problems occur during an experiment.Typical raw data along with calculated relative permeabilities are shown for both two-phase and permeabilities are shown for both two-phase and three-phase experiments.PURPOSE AND SCOPE PURPOSE AND SCOPETwo major drawbacks to widespread use of the centrifuge method for measuring relative permeabilities have been the difficulty in obtaining good data and the tedium associated with obtaining any data. Both of these drawbacks are virtually eliminated by the present system whose important hardware and software components are described below.Centrifuges have been used to measure not only relative permeabilities but also capillary pressures. In a relative permeability experiment, the centrifuge is run at a high enough speed to overcome a capillary end-effect and liquid production is monitored as a function of time. On the other hand, capillary pressure experiments entail increasing the speed in steps and measuring steady-state liquid production at each step. The relative permeability experiment is, therefore, the harder one to do-after-all, if you can measure production as a function of time you can certainly measure total production at a given rotational speed. Consequently, production at a given rotational speed. Consequently, we confine our illustrations of typical data to relative permeability measurements. permeability measurements. In general, the worth of our new system increases along with the required amount of data collection. This is best exemplified by measurements of three-phase relative permeabilities. These depend on two saturations and, permeabilities. These depend on two saturations and, consequently, require many experiments to elucidate the functional dependencies.The following sections provide (i) a brief sketch of the centrifuge method for measuring relative permeabilities, (ii) benefits of this method over permeabilities, (ii) benefits of this method over alternatives, (iii) a review of centrifuge problems of the past, (iv) our solutions to these problems, and (v) typical data and calculated relative permeabilities.THE CENTRIFUGE METHODCentrifuge measurements of relative permeabilities entail monitoring the liquid production from rock samples initially saturated uniformly with one or two phases. The liquids are collected in transparent tubes connected to the rock sample holders and production is monitored as a function of time. Figure l shows a schematic diagram of a typical sample holder and collection tube.Hagoort and Van Spronsen show for two-phase and three-phase flows respectively that outflow saturations and corresponding relative permeabilities can be calculated from liquid production via the following equations:(1)(2) Keywords: saturation, capacitor, flow in porous media, centrifuge method, relative permeability, interface, voltage, liquid production, photodiode array, upstream oil & gas Subjects: Reservoir Fluid Dynamics, Flow in porous media This content is only available via PDF. 1983. Society of Petroleum Engineers You can access this article if you purchase or spend a download.