Publication | Closed Access
Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment
34
Citations
0
References
2002
Year
Tibial ResectionCorrect Tibial AlignmentImaging AnatomyMedical ImagingMedicineOsteoarthritisInterventional RadiologySurgeryJoint ReplacementArthroscopic TechniqueRadiological AlignmentRadiologic ImagingProspective TrialTibial ProsthesisOrthopaedic SurgeryRadiologyHealth Sciences
We undertook a prospective, randomised study of 135 total knee arthroplasties to determine the most accurate and reliable technique for alignment of the tibial prosthesis. Tibial resection was guided by either intramedullary or extramedullary alignment jigs. Of the 135 knees, standardised postoperative radiographs suitable for assessment were available in 100. Correct tibial alignment was found in 85% of the intramedullary group compared with 65% of the extramedullary group (p = 0.019). We conclude that intramedullary guides are superior to extramedullary instruments for alignment of the tibial prosthesis.