Underwater motion analysis is hampered by refraction‑induced image deformation at the water‑air interface, which current calibration‑reconstruction algorithms cannot correct, leading to large reconstruction errors. This paper reviews the nature of refraction‑induced deformation, the shortcomings of the Direct Linear Transformation method, experimental factors, and alternative strategies, and proposes developing algorithms that correct refraction. Error reduction can be achieved with localized DLT and double‑plane methods, and by adjusting experimental conditions or calibration frame characteristics. Although refraction error cannot be eliminated, accuracy can be improved by manipulating experimental conditions or calibration frame characteristics. Keywords: calibration frame, double‑plane method, extrapolation error, image deformation, localized DLT, underwater calibration‑reconstruction.

Abstract

Abstract One of the most serious obstacles to accurate quantification of the underwater motion of a swimmer's body is image deformation caused by refraction. Refraction occurs at the water‐air interface plane (glass) owing to the density difference. Camera calibration‐reconstruction algorithms commonly used in aquatic research do not have the capability to correct this refraction‐induced nonlinear image deformation and produce large reconstruction errors. The aim of this paper is to provide a thorough review of: the nature of the refraction‐induced image deformation and its behaviour in underwater object‐space plane reconstruction; the intrinsic shortcomings of the Direct Linear Transformation (DLT) method in underwater motion analysis; experimental conditions that interact with refraction; and alternative algorithms and strategies that can be used to improve the calibration‐reconstruction accuracy. Although it is impossible to remove the refraction error completely in conventional camera calibration‐reconstruction methods, it is possible to improve the accuracy to some extent by manipulating experimental conditions or calibration frame characteristics. Alternative algorithms, such as the localized DLT and the double‐plane method are also available for error reduction. The ultimate solution for the refraction problem is to develop underwater camera calibration and reconstruction algorithms that have the capability to correct refraction. Keywords: calibration framedouble‐plane methodextrapolation errorimage deformationlocalized DLTunderwater calibration‐reconstruction

References

20