Electrical Testing for Detection and Classification of Open Damper Bar and Shorted Field Winding Failures in Wound Field Synchronous Motors
13
Citations
21
References
2022
Year
Fault DiagnosisCondition MonitoringElectric MachineEngineeringOpen Damper BarNew Test MethodsField WindingBroken Damper BarsDiagnosisStructural Health MonitoringElectrical DriveEngineering Failure AnalysisFault DetectionAutomatic Fault DetectionElectrical Testing
Broken damper bars and shorted field winding turns degrade the starting and running performance of industrial wound field synchronous motors (WFSMs), and can lead to a forced outage of the motor and driven process. Testing of WFSM rotor windings mainly relies on offline tests, which cannot be performed frequently and are known to lack reliability. Shorted turns in the field winding can be detected online from the airgap flux measurement, but require a sensor to be installed on the stator bore. In this article, new test methods for detecting and classifying damper and field winding faults based on electrical signals are proposed. The proposed methods can provide remote testing at motor standstill and during the motor starting transient without disassembling the motor. Test results on a 30 kW, salient pole WFSM show that both test methods can provide reliable detection and classification of damper and field winding faults.