IEEE Transactions on Industry Applications · 2006 · 125 citations · 14 references
EngineeringElectrical EngineeringCondition AssessmentElectric MachinesPower ElectronicsBrushless Dc MachinesCondition MonitoringGenerator OperationPower QualitySynchronous MachinesThree-phase MachinesBrushless Direct Current MachinesCondition Monitoring SystemsExperimental MethodologyGround Fault DetectionGround Fault IdentificationStator WindingsSynchronous Generator OperationThree-phase Synchronous Machines
This paper presents experimental and theoretical analyses used to establish electrical features that can be utilized as indicators of armature winding, field winding, or rectifier diode deterioration in brushless three-phase synchronous generators before the imperfection progresses to become a ground fault. This paper begins with the description of a 5-kVA synchronous generator specifically designed and constructed to allow for simulation of armature winding, field winding, or rectifier diode deterioration in a brushless machine. Subsequently, a description of the experimental methodology and the results of experiments are presented. Specific features that can be used as indicators of the deterioration are described, and a theoretical basis for them is provided. The proposed features can be obtained continuously during normal generator operation. As such, they can be used as a basis for both brushless and brush-fed synchronous generator health monitoring applications
14