Endoscopic ultrasound-guided through-the-needle microforceps biopsy and needle-based confocal laser-endomicroscopy increase detection of potentially malignant pancreatic cystic lesions: A single-center study

Carlos Robles‐Medranda, Juan I. Olmos, Miguel Puga-Tejada, Roberto Oleas, Jorge Baquerizo‐Burgos, Martha Arevalo-Mora, Raquel Del Valle Zavala, João Autran Nebel, Daniel Calle Loffredo, Hannah Pitanga‐Lukashok

World Journal of Gastrointestinal Endoscopy · 2022 · 10 citations · 15 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: Currently, there is insufficient data about the accuracy in the diagnosing of pancreatic cystic lesions (PCLs), especially with novel endoscopic techniques such as with direct intracystic micro-forceps biopsy (mFB) and needle-based confocal laser-endomicroscopy (nCLE). AIM: To compare the accuracy of endoscopic ultrasound (EUS) and associated techniques for the detection of potentially malignant PCLs: EUS-guided fine needle aspiration (EUS-FNA), contrast-enhanced EUS (CE-EUS), EUS-guided fiberoptic probe cystoscopy (cystoscopy), mFB, and nCLE. METHODS: the EUS-guided techniques and/or EUS-guided biopsy when available (EUS malignancy detection). RESULTS: 0.001 compared with EUS-alone). CONCLUSION: The combined use of EUS-guided mFB and nCLE improves detection of potentially malignant PCLs compared with EUS-alone, EUS-FNA, CE-EUS or cystoscopy.

References

15