Publication | Closed Access
Fire and Blast Protection for Multi-Strand Stay Cables of Rod El Farag Axis Bridge
11
Citations
4
References
2022
Year
Bridge DesignStructural IntegrityEngineeringStay CablesFire EngineeringFire SafetyStructural Fire EngineeringCivil EngineeringBlast Protection SystemStructural Health MonitoringStructural Fire SafetyStructural ApplicationMulti-strand Stay CablesBlast ProtectionStructural MechanicsStructural EngineeringProtection System
Long span cable-stayed bridges face risks of fire and explosion accidents caused by vehicles transporting fuel or chemicals. Such accidents may lead to damage to the stay cables, which in turn reduces the load capability of the bridge. This report introduces a newly developed fire and blast protection system for the multi-strand stay cables of Rod El Farag Axis Bridge in Egypt. The protection system consists of a thermal insulation blanket wrapped on cables and a steel tube covered with an anti-blast layer. Fire and blast tests were carried out to verify the effectiveness of the developed protection system.
| Year | Citations | |
|---|---|---|
Page 1
Page 1