Communications - Scientific letters of the University of Zilina · 2012 · 16 citations · 4 references
EngineeringCivil EngineeringMechanical Behavior Of MaterialsStructural AnalysisStructural EngineeringNonlinear Structural AnalysisSteel StructuresStrain AnalysisStrain MeasurementStructural MechanicsStructural TestingExperimental Truss TestingLinear Elastic BehaviorMeasurementStrain MonitoringStructural Performance TestingStructural Strain MonitoringTest Data InterpretationTruss Elements
The paper deals with strain measuring of bolted steel lattice high voltage tower structure on the test field. This measurement was associated to the test according to international standard IEC 60652, Ed. 2.0. If the tower is simulated as a truss structure and we expect the linear behavior of this object then the test data and calculation may show variations. The displacements of screw joint were detected as a source of this variation or non linear properties of structure. The key to this conclusion was detection of peak in measurement data.
4
Use of Trefftz functions in non-linear BEM/FEM
V. Kompiš, Milan Toma, Milan Žmindák et al. · Computers & Structures · 2004 · 11 citations