Accuracy of Temporo-Spatial and Lower Limb Joint Kinematics Parameters Using OpenPose for Various Gait Patterns With Orthosis

49

Citations

41

References

2021

Year

Abstract

A cost-effective gait analysis system without attachments and specialized large environments can provide useful information to determine effective treatment in clinical sites. This study investigates the capability of a single camera-based pose estimation system using OpenPose (OP) to measure the temporo-spatial and joint kinematics parameters during gait with orthosis. Eleven healthy adult males walked under different conditions of speed and foot progression angle (FPA). Temporo-spatial and joint kinematics parameters were measured using a single camera-based system with OP and a three-dimensional motion capture system. The limit of agreement, mean absolute error, absolute agreement (ICC<sub>2, 1</sub>), and relative consistency (ICC<sub>3, 1</sub>) between the systems under each condition were assessed for reliability and validity. The results demonstrated that most of the ICC for temporo-spatial parameters and hip and knee kinematics parameters were good to excellent (0.60 - 0.98). Conversely, most of the ICC for ankle kinematics in all conditions were poor to fair (< 0.60). Thus, the gait analysis using OP can be used as a clinical assessment tool for determining the temporo-spatial, hip, and knee sagittal plane angles during gait.