Neutron energy spectrum measurement using CLYC7-based compact neutron emission spectrometer in the Large Helical Device

Siriyaporn Sangaroon, K. Ogawa, M. Isobe, Makoto Kobayashi, Y. Fujiwara, S. Kamio, Hitoshi Yamaguchi, R. Seki, H. Nuga, Sho Toyama,

Journal of Instrumentation · 2021 · 21 citations · 22 references

DOIFull text

Open access

Concepts

Abstract

Abstract Tangential compact neutron emission spectrometer (CNES) based on the Cs 2 LiYCl 6 :Ce with 7 Li-enrichment (CLYC7) scintillator is newly installed in the Large Helical Device (LHD). Measurement of neutron energy spectrum was performed using CNES in tangential neutral beam (NB) heated deuterium plasma discharges. The Doppler shift of neutron energy according to the direction of tangential NB injection has been obtained. When the fast ions moving away from the CNES, lower shifted neutron energy is obtained, whereas the upper shifted neutron energy is obtained when the fast ions moving toward the CNES. The obtained neutron energy is almost consistent with the virgin deuterium-deuterium neutron energy evaluated by the simple two-body kinematic calculation.