2021 IEEE 22nd Workshop on Control and Modelling of Power Electronics (COMPEL) · 2021 · 18 citations · 7 references
EngineeringElectrical EngineeringBridge EngineeringCircuit TheoryPower ElectronicsConverter TopologiesDc-dc ConversionDc-dc ConvertersHigh-frequency Power ConversionMagnetic Circuit AnalysisMagnetic ComponentsConverter Topology DesignDual Active Bridge ConvertersHigh-frequency Ac-ac ConversionInductance CalculationMagnetic Leakage InductanceSoft SwitchingSoft-switching Converter TopologiesSoft-switching Converters
The magnetizing inductance of the high-frequency transformer in the dual-active bridge (DAB) converter is usually assumed to be much larger than its leakage inductance, thereby the magnetizing current can be negligible. However, ignoring the magnetizing current will lead to an error in the DAB converter design process. This paper analyzes the operation and performance of the DAB converter for a general case in which the transformer magnetizing inductance is taken into consideration. The analysis shows that the magnetizing inductance impacts the soft-switching region, the power transfer capability, and the leakage inductor current. A simulation case study is provided to verify the analysis. A DAB converter prototype is built to experimentally validate the analysis as well.
7
An overall study of a Dual Active Bridge for bidirectional DC/DC conversion
Alberto Rodríguez, J. Sebastián, Diego G. Lamar et al. · 2010 · 300 citations