IEEE Sensors Journal · 2021 · 18 citations · 18 references
EngineeringElectrical EngineeringInstrumentationPower ElectronicsTime Series AnalysisCondition MonitoringElectrical MeasurementElectrical MetrologyElectrical System DiagnosticsInsulation SystemsPower QualityCable InsulationCable MaintenanceCable SystemsCondition Monitoring Of InsulationInsulation Defect DetectionInsulation DiagnosticsInsulation Fault DetectionInsulation Monitoring
The deterioration of cable insulation is a widely acknowledged problem, and detection lays the foundation for maintenance and overhaul. The measurement of Tangent delta (tan <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\boldsymbol {\delta }$ </tex-math></inline-formula> ) at very low frequency (VLF) works well on cable insulation detection, nevertheless the conventional method could only be conducted offline, where the power outage is usually required, interrupting the normal operation. To break thus a limitation, an advanced online method is proposed, and tan <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\boldsymbol {\delta }$ </tex-math></inline-formula> would be calculated based on the measurement of an artificially injected VLF voltage and that of the VLF leakage current through cable insulation. To coordinate with this method, an injecting source, with the comprehensive self-protection and the by-pass channel for power-frequency signals, is developed to safely inject a VLF voltage to the power system, and a monitoring system, with an accuracy better than <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pm 0.3~\boldsymbol {\mu }\text{A}$ </tex-math></inline-formula> , is established to obtain the injected voltage’s and leakage current’s waveforms, which would be used to further calculate tan <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\boldsymbol {\delta }$ </tex-math></inline-formula> with the cross-correlation algorithm. In addition, this method, as well as developed devices, is applied on several cables in China Electric Power Research Institute, and the measuring results keep consistent with the actual conditions, which verifies the validity.
18
Magnetic sensors and their applications
J. Lenz, Shulamit Edelstein · IEEE Sensors Journal · 2006 · 1.3K citations
Characterization of Ageing for MV Power Cables Using Low Frequency Tan δ Diagnostic Measurements
Jean Carlos Hernandez-Mejia, Ronald G. Harley, Nigel Hampton et al. · IEEE Transactions on Dielectrics and Electrical Insulation · 2009 · 50 citations
Natural Sciences, Electrical Engineering, Materials Science +17