International Journal for Numerical Methods in Biomedical Engineering · 2022 · 93 citations · 77 references
EngineeringBioengineeringBiomedical Engineering3D ModelingComputational Fluid DynamicsFluid DynamicsCardiovascular BiomechanicsCardiovascular System ModelingGeometry ProcessingHemodynamicsHemodynamics ModelingBlood FlowBlood Flow SimulationCardiovascular Fluid DynamicsComputational HemodynamicsDesign ParameterizationLumped-parameter Hemodynamic ModelsOne-dimensional Blood Flow ModelsThree-dimensional Computational Fluid Dynamics
Three-dimensional (3D) cardiovascular fluid dynamics simulations typically require hours to days of computing time on a high-performance computing cluster. One-dimensional (1D) and lumped-parameter zero-dimensional (0D) models show great promise for accurately predicting blood bulk flow and pressure waveforms with only a fraction of the cost. They can also accelerate uncertainty quantification, optimization, and design parameterization studies. Despite several prior studies generating 1D and 0D models and comparing them to 3D solutions, these were typically limited to either 1D or 0D and a singular category of vascular anatomies. This work proposes a fully automated and openly available framework to generate and simulate 1D and 0D models from 3D patient-specific geometries, automatically detecting vessel junctions and stenosis segments. Our only input is the 3D geometry; we do not use any prior knowledge from 3D simulations. All computational tools presented in this work are implemented in the open-source software platform SimVascular. We demonstrate the reduced-order approximation quality against rigid-wall 3D solutions in a comprehensive comparison with N = 72 publicly available models from various anatomies, vessel types, and disease conditions. Relative average approximation errors of flows and pressures typically ranged from 1% to 10% for both 1D and 0D models, measured at the outlets of terminal vessel branches. In general, 0D model errors were only slightly higher than 1D model errors despite requiring only a third of the 1D runtime. Automatically generated ROMs can significantly speed up model development and shift the computational load from high-performance machines to personal computers.
77
Irène Vignon-Clémentel, C. Alberto Figueroa, Kenneth E. Jansen et al. · Computer Methods in Applied Mechanics and Engineering · 2005 · 637 citations
Engineering, Biomedical Engineering, Computational Engineering +16
Georgios Kissas, Yibo Yang, Eileen Hwuang et al. · Computer Methods in Applied Mechanics and Engineering · 2019 · 629 citations · Full text