Optics Express · 2021 · 23 citations · 36 references
EngineeringBiomedical EngineeringBiomedical ImagingBiomedical OpticsDiagnostic ImagingImage ReconstructionImagingOptical CoherenceOptical Coherence TomographyOptical ImagingOptical TomographyAxial ResolutionAxial Resolution ImprovementBandwidthDiscrete Fourier TransformImage Super-resolutionSpectral EstimationSuper-resolutionVolumetric Imaging
Spectral-estimation OCT (SE-OCT) is a computational method to enhance the axial resolution beyond the traditional bandwidth limit. However, it has not yet been used widely due to its high computational load, dependency on user-optimized parameters, and inaccuracy in intensity reconstruction. In this study, we implement SE-OCT using a fast implementation of the iterative adaptive approach (IAA). This non-parametric spectral estimation method is optimized for use on OCT data. Both in simulations and experiments we show an axial resolution improvement with a factor between 2 and 10 compared to standard discrete Fourier transform. Contrary to parametric methods, IAA gives consistent peak intensity and speckle statistics. Using a recursive and fast reconstruction scheme the computation time is brought to the sub-second level for a 2D scan. Our work shows that SE-OCT can be used for volumetric OCT imaging in a reasonable computation time, thus paving the way for wide-scale implementation of super-resolution OCT.
36
David Huang, Eric A. Swanson, Charles P. Lin et al. · Science · 1991 · 13.7K citations
High-resolution frequency-wavenumber spectrum analysis
J. Capon · Proceedings of the IEEE · 1969 · 6.2K citations
Tarik Yardibi, Jian Li, Petre Stoica et al. · IEEE Transactions on Aerospace and Electronic Systems · 2010 · 680 citations · Full text