The Nephron journals/Nephron journals · 2021 · 14 citations · 18 references
MedicineInternal MedicineNephrologyDiabetologyDialysisHemodialysisContinuous Glucose MonitoringDiabetes ManagementDiabetes MellitusGlycemic ControlGlycemic MonitoringRenal Function TestsGlomerular Filtration Rate MeasurementGlucose ConcentrationGlucose MonitoringGlucose QuantificationGlucose SensorsGlycemic BiomarkersHemoglobin A1c TestingInterstitial Glucose Measurement
<b><i>Introduction:</i></b> Shortened erythrocyte life span and erythropoietin-stimulating agents may affect hemoglobin A<sub>1c</sub> (HbA<sub>1c</sub>) levels in patients receiving peritoneal dialysis (PD). We compared HbA<sub>1c</sub> with interstitial glucose measured by continuous glucose monitoring (CGM) in patients with type 2 diabetes receiving PD. <b><i>Methods:</i></b> Fourteen days of CGM (Ipro2, Medtronic) were performed in 23 patients with type 2 diabetes receiving PD and in 23 controls with type 2 diabetes and an estimated glomerular filtration rate over 60 mL/min/1.73 m<sup>2</sup>. Patients were matched on gender and age (±5 years). HbA<sub>1c</sub> (mmol/mol), its derived estimate of mean plasma glucose (eMPG<sub>A1c</sub>) (mmol/L), and fructosamine (µmol/L) were measured at the end of the CGM period and compared with the mean sensor glucose (mmol/L) from CGM. <b><i>Results:</i></b> In the PD group, mean sensor glucose was 0.98 (95% confidence interval (CI): 0.43–1.54) mmol/L higher than the eMPG<sub>A1c</sub> compared with the control group (<i>p</i> = 0.002) where glucose levels were nearly identical (−0.05 (95% CI: −0.35–0.25) mmol/L). A significant association was found between fructosamine and mean sensor glucose using linear regression with no difference between slopes (<i>p</i> = 0.89) or y-intercepts (<i>p</i> = 0.28). <b><i>Discussion/Conclusion:</i></b> HbA<sub>1c</sub> underestimates mean plasma glucose levels in patients with type 2 diabetes receiving PD. However, the clinical significance of this finding is undetermined. Fructosamine seems to more accurately reflect glycemic status. CGM or fructosamine could complement HbA<sub>1c</sub> to increase the accuracy of glycemic monitoring in the PD population.
18
Translating the A1C Assay Into Estimated Average Glucose Values
David M. Nathan, J.C. Kuenen, Rikke Borg et al. · Diabetes Care · 2008 · 1.8K citations · Full text
Global Trends in Rates of Peritoneal Dialysis
Arsh K. Jain, Peter G. Blake, Peter E. Cordy et al. · Journal of the American Society of Nephrology · 2012 · 548 citations · Full text
Medicine, Nephrology, Dialysis +4
Red Blood Cell Survival in Long-term Dialysis Patients
Frederiek E. Vos, John Schollum, Carolyn V. Coulter et al. · American Journal of Kidney Diseases · 2011 · 160 citations
Medicine, Hematology, Nephrology +14