Journal of Anatomy · 2021 · 24 citations · 32 references
DentistryMaxillofacial RadiologySurgeryDiagnostic ImagingMaxillofacial ImagingReconstructive SurgeryComputed TomographyFacial ReconstructionImage ReconstructionMaxillofacial Defect ReconstructionOrbital AnatomyThree-dimensional ReconstructionGround Truth VerificationGround-truth ValidationOrbital Bone DefectsOrbital Floor ImagingOrbital Floor RepairReconstruction Of Orbital DefectsShapeStatistical Shape Analysis
PURPOSE: The current standard in reconstructing defects of the orbital floor, by using the concept of mirroring, is time-consuming and ignores the natural asymmetry of the skull. By using a statistical shape model (SSM), the reconstruction can be automatized and improved in accuracy. The present study aims to show the possibilities of the virtual reconstruction of artificial defects of the orbital floor using an SSM and its potentials for clinical implementation. METHODS: Based on 131 unaffected CT scans of the midface, an SSM was created which contained the shape variability of the orbital floor. Nineteen midface CT scans, that were not included in the SSM, were manually segmented to establish ground truth (control group). Then artificial defects of larger and smaller sizes were created and reconstructed using SSM (Group I) and the gold standard of mirroring (Group II). Eventually, a comparison to the surface of the manual segmentation (control group) was performed. RESULTS: The proposed method of reconstruction using an SSM leads to more precise reconstruction results, compared with the conventional method of mirroring. Whereas mirroring led to the reconstruction errors of 0.7 mm for small defects and 0.73 mm for large defects, reconstruction using SSM led to deviations of 0.26 mm (small defect) and, respectively, 0.34 mm (large defect). CONCLUSIONS: The presented approach is an effective and accurate method for reconstructing the orbital floor. In connection with modern computer-aided design and manufacturing, individual patient-specific implants could be produced according to SSM-based reconstructions and could replace current methods using manual bending techniques. By acknowledging the natural asymmetry of the human skull, the SSM-based approach achieves higher accuracy in reconstructing injured orbits.
32
R: A Language and Environment for Statistical Computing
R Core Team · 2000 · 353K citations · Full text
Natural Sciences, Computer Science, Statistical Computing +10
3D Slicer as an image computing platform for the Quantitative Imaging Network
Andriy Fedorov, Reinhard Beichel, Jayashree Kalpathy–Cramer et al. · Magnetic Resonance Imaging · 2012 · 8.9K citations · Full text
Arts, Computer Science, Radiology +12