Physics and Imaging in Radiation Oncology · 2021 · 18 citations · 26 references
MedicineOncologyRadiologyDiagnostic RadiologyRadiation DetectionRadiobiologyBiological Effects Of RadiationComputed TomographyRadiation SensitivityRadiation TherapyRadiation ToxicityRadiographic ImagingControl Group DesignDark-field ImagingEarly DiagnosisIrradiation DamageMatched Control GroupMurine ModelsRadiation DamageTomography
BACKGROUND AND PURPOSE: Radiotherapy of thoracic tumours can lead to side effects in the lung, which may benefit from early diagnosis. We investigated the potential of X-ray dark-field computed tomography by a proof-of-principle murine study in a clinically relevant radiotherapeutic setting aiming at the detection of radiation-induced lung damage. MATERIAL AND METHODS: Six mice were irradiated with 20 Gy to the entire right lung. Together with five unirradiated control mice, they were imaged using computed tomography with absorption and dark-field contrast before and 16 weeks post irradiation. Mean pixel values for the right and left lung were calculated for both contrasts, and the right-to-left-ratio R of these means was compared. Radiologists also assessed the tomograms acquired 16 weeks post irradiation. Sensitivity, specificity, inter- and intra-reader accuracy were evaluated. RESULTS: In absorption contrast the group-average of R showed no increase in the control group and increased by 7% (p = 0.005) in the irradiated group. In dark-field contrast, it increased by 2% in the control group and by 14% (p = 0.005) in the irradiated group. Specificity was 100% for both contrasts but sensitivity was almost four times higher using dark-field tomography. Two cases were missed by absorption tomography but were detected by dark-field tomography. CONCLUSIONS: The applicability of X-ray dark-field computed tomography for the detection of radiation-induced lung damage was demonstrated in a pre-clinical mouse model. The presented results illustrate the differences between dark-field and absorption contrast and show that dark-field tomography could be advantageous in future clinical settings.
26
Hard-X-ray dark-field imaging using a grating interferometer
Franz Pfeiffer, Martin Bech, Oliver Bunk et al. · Nature Materials · 2008 · 1.1K citations
Natural Sciences, Physics, Radiology +14
John Wong, Elwood P. Armour, Peter Kazanzides et al. · International Journal of Radiation Oncology*Biology*Physics · 2008 · 361 citations · Full text
Veterinary Medicine, Radiology, Veterinary Diagnostic Imaging +14
In-vivo dark-field and phase-contrast x-ray imaging
Martin Bech, Arne Tapfer, Astrid Velroyen et al. · Scientific Reports · 2013 · 164 citations · Full text