Physics in Medicine and Biology · 2021 · 40 citations · 53 references
MedicineRadiologyBiomedical ImagingDiagnostic RadiologyOncologic Nuclear MedicineComputed Tomography Dose ManagementImage-guided RadiotherapyPhantom DosimetryProton DosimetrySkull Base ImagingTreatment Planning Dose CalculationAdaptive Proton TherapyAdaptive Radiation Therapy PlanningAdaptive Radiotherapy DosimetryAdaptive Radiotherapy PlanningComputational PhantomsOnline Adaptive RadiotherapyProton Therapy DosimetryProton Therapy Phantom Dosimetry
Anatomical changes during proton therapy require rapid treatment plan adaption to mitigate the associated dosimetric impact. This in turn requires a highly efficient workflow that minimizes the time between imaging and delivery. At the Paul Scherrer Institute, we have developed an online adaptive workflow, which is specifically designed for treatments in the skull-base/cranium, with the focus set on simplicity and minimizing changes to the conventional workflow. The dosimetric and timing performance of this daily adaptive proton therapy (DAPT) workflow has been experimentally investigated using an in-house developed DAPT software and specifically developed anthropomorphic phantom. After a standard treatment preparation, which includes the generation of a template plan, the treatment can then be adapted each day, based on daily imaging acquired on an in-room CT. The template structures are then rigidly propagated to this CT and the daily plan is fully re-optimized using the same field arrangement, DVH constraints and optimization settings of the template plan. After a dedicated plan QA, the daily plan is delivered. To minimize the time between imaging and delivery, clinically integrated software for efficient execution of all online adaption steps, as well as tools for comprehensive and automated QA checks, have been developed. Film measurements of an end-to-end validation of a multi-fraction DAPT treatment showed high agreement to the calculated doses. Gamma pass rates with a 3%/3 mm criteria were >92% when comparing the measured dose to the template plan. Additionally, a gamma pass rate >99% was found comparing measurements to the Monte Carlo dose of the daily plans reconstructed from the logfile, accumulated over the delivered fractions. With this, we experimentally demonstrate that the described adaptive workflow can be delivered accurately in a timescale similar to a standard delivery.
53
Dimitris Bertsimas, Melvyn Sim · Operations Research · 2004 · 4.4K citations
Bas W. Raaymakers, Ina M. Jürgenliemk‐Schulz, G.H. Bol et al. · Physics in Medicine and Biology · 2017 · 533 citations · Full text
Gafchromic EBT film dosimetry in proton beams
Zhao Li, Indra J. Das · Physics in Medicine and Biology · 2010 · 142 citations