Acta Biomaterialia · 2021 · 24 citations · 33 references
Natural SciencesMaterials EngineeringMaterials ScienceBiocompatibilityBiomaterialsCorrosion ScienceBone TissueCorrosion EngineeringCorrosion TestingCorrosion-resistant MaterialsImplant MaterialsAlloyingAlloying ElementsBiodegradable ImplantsCorrosion ByproductsImplant DegradationImplant-bone InteractionMagnesium AlloysNeutron Imaging
Extensive research is being conducted on magnesium (Mg) alloys for bone implant manufacturing, due to their biocompatibility, biodegradability and mechanical properties. Gadolinium (Gd) is among the most promising alloying elements for property control in Mg alloy implants; however, its toxicity is controversial. Investigating Gd behavior during implant corrosion is thus of utmost importance. In this study, we analyzed the degradation byproducts at the implant site of biodegradable Mg-5Gd and Mg-10Gd implants after 12 weeks healing time, using a combination of different imaging techniques: histology, energy-dispersive x-ray spectroscopy (EDX), x-ray microcomputed tomography (µCT) and neutron µCT. The main finding has been that, at the healing time in exam, the corrosion appears to have involved only the Mg component, which has been substituted by calcium and phosphorus, while the Gd remains localized at the implant site. This was observed in 2D by means of EDX maps and extended to 3D with a novel application of neutron tomography. X-ray fluorescence analysis of the main excretory organs also did not reveal any measurable accumulation of Gd, further reinforcing the conclusion that very limited or no removal at all of Gd-alloy happened during degradation. STATEMENT OF SIGNIFICANCE: Gadolinium is among the most promising alloying elements for property control in biodegradable magnesium alloy implants, but its toxicity is controversial and its behavior during corrosion needs to be investigated. We combine 2D energy dispersive x-ray spectroscopy and 3D neutron and x-ray tomography to image the degradation of magnesium-gadolinium implants after 12 weeks of healing time. We find that, at the time in exam, the corrosion has involved only the magnesium component, while the gadolinium remains localized at the implant site. X-ray fluorescence analysis of the main excretory organs also does not reveal any measurable accumulation of Gd, further reinforcing the conclusion that very limited or no removal at all of Gd-alloy has happened during degradation.
33
Fundamentals and advances in magnesium alloy corrosion
M. Esmaily, Jan‐Erik Svensson, S. Fajardo et al. · Progress in Materials Science · 2017 · 2K citations · Full text
Natural Sciences, Materials Engineering, Materials Science +17
Fast and flexible X-ray tomography using the ASTRA toolbox
Wim van Aarle, Willem Jan Palenstijn, Jeroen Cant et al. · Optics Express · 2016 · 1K citations · Full text
Stripe and ring artifact removal with combined wavelet—Fourier filtering
Beat Münch, Pavel Trtik, Federica Marone et al. · Optics Express · 2009 · 677 citations · Full text