European Heart Journal - Quality of Care and Clinical Outcomes · 2021 · 12 citations · 10 references
MedicineCardiologyClinical CardiologyElectrophysiologyInterventional CardiologyAtrial FibrillationCardiac AssessmentCardiac Risk AssessmentCardiovascular MonitoringMedical Device EvaluationPatient MonitoringArrhythmia DetectionArrhythmia DiagnosisAtrial Fibrillation MonitoringDevice-detected Atrial FibrillationMedical IndicationObservational Study EvaluationPrimary Outcome AnalysisReal-world Performance Evaluation
AIM: Implantable loop recorders (ILRs) are now routinely implanted for long-term cardiac monitoring in the clinical setting. The aim of this study was to examine the real-world performance of these devices focusing on the management changes made in response to ILR-recorded data. METHODS AND RESULTS: This was a single-centre, prospective observational study of consecutive patients undergoing ILR implantation. All patients who underwent implantation of a Medtronic Reveal LINQ device from September 2017 to June 2019 at Barts Heart Centre were included. Five hundred and one patients were included. Three hundred and two (60%) patients underwent ILR implantation for an indication of pre-syncope/syncope, 96 (19%) for palpitations, 72 (14%) for atrial fibrillation (AF) detection with a history of cryptogenic stroke, and 31 (6%) for high risk of serious cardiac arrhythmia. The primary outcome of this study was that an ILR-derived diagnosis altered management in 110 patients (22%). Secondary outcomes concerned subgroup analyses by indication: in patients who presented with syncope/pre-syncope, a change in management resulting from ILR data was positively associated with age [hazard ratio (HR) 1.04, 95% confidence interval 1.02-1.06; P < 0.001] and negatively associated with a normal electrocardiogram at baseline (HR 0.54 [0.31-0.93]; P = 0.03). Few patients (1/57, 2%) aged <40 years in this group underwent device implantation, compared to 19/62 patients (31%) aged 75 years and over (P = 0.0024). Out of 183 (12%) patients, 22 in the 40-74 age range had a device implanted. Among patients who underwent ILR insertion following cryptogenic stroke, 13/72 (18%) had AF detected, leading to a decision to commence anticoagulation. CONCLUSION: These results inform the utility of ILR in the clinical setting. Diagnoses provided by ILR that lead to changes in management are rare in patients under age 40, particularly following syncope, pre-syncope, or palpitations. In older patients, new diagnoses are frequently made and trigger important changes in treatment.
10
R: A Language and Environment for Statistical Computing
R Core Team · 2000 · 353K citations · Full text
Natural Sciences, Computer Science, Statistical Computing +10
2018 ESC Guidelines for the diagnosis and management of syncope
Michele Brignole, Frederik J. de Lange, Jean‐Claude Deharo et al. · European Heart Journal · 2018 · 1.9K citations · Full text
Richard A. Bernstein, Hooman Kamel, Christopher B. Granger et al. · JAMA · 2021 · 201 citations · Full text