Can Public Spaces Effectively Be Used as Cleaner Indoor Air Shelters during Extreme Smoke Events?

Amanda J. Wheeler, Ryan W. Allen, Kerryn Lawrence, Chris Roulston, Jennifer Powell, Grant J. Williamson, Penelope Jones, Fabienne Reisen, Geoffrey Morgan, Fay H. Johnston

International Journal of Environmental Research and Public Health · 2021 · 22 citations · 17 references

DOIFull text

Open access

Abstract

During extreme air pollution events, such as bushfires, public health agencies often recommend that vulnerable individuals visit a nearby public building with central air conditioning to reduce their exposure to smoke. However, there is limited evidence that these "cleaner indoor air shelters" reduce exposure or health risks. We quantified the impact of a "cleaner indoor air shelter" in a public library in Port Macquarie, NSW, Australia when concentrations of fine particulate matter (PM<sub>2.5</sub>) were elevated during a local peat fire and nearby bushfires. Specifically, we evaluated the air quality improvements with central air conditioning only and with the use of portable high efficiency particulate air (HEPA) filter air cleaners. We measured PM<sub>2.5</sub> from August 2019 until February 2020 by deploying pairs of low-cost PM<sub>2.5</sub> sensors (i) inside the main library, (ii) in a smaller media room inside the library, (iii) outside the library, and (iv) co-located with regulatory monitors located in the town. We operated two HEPA cleaners in the media room from August until October 2019. We quantified the infiltration efficiency of outdoor PM<sub>2.5</sub> concentrations, defined as the fraction of the outdoor PM<sub>2.5</sub> concentration that penetrates indoors and remains suspended, as well as the additional effect of HEPA cleaners on PM<sub>2.5</sub> concentrations. The infiltration efficiency of outdoor PM<sub>2.5</sub> into the air-conditioned main library was 30%, meaning that compared to the PM<sub>2.5</sub> concentration outdoors, the concentrations of outdoor-generated PM<sub>2.5</sub> indoors were reduced by 70%. In the media room, when the HEPA cleaners were operating, PM<sub>2.5</sub> concentrations were reduced further with a PM<sub>2.5</sub> infiltration efficiency of 17%. A carefully selected air-conditioned public building could be used as a cleaner indoor air shelter during episodes of elevated smoke emissions. Further improvements in indoor air quality within the building can be achieved by operating appropriately sized HEPA cleaners.

References

17