Scientific Reports · 2021 · 34 citations · 53 references
MedicineCardiologyClinical SciencesClinical CardiologyDiagnostic ImagingInterventional CardiologyCardiac ImagingCardiovascular ImagingCoronary AngiographyCoronary Artery DiseaseCoronary Artery ImagingIntracoronary ImagingBifurcation Lesion ClassificationBifurcation Lesion ImagingCoronary Artery Disease ImagingCoronary Bifurcation ImagingCoronary Flow AssessmentCoronary Lesion AssessmentHemodynamic ImagingHigh-resolution Coronary Imaging
Conventional invasive diagnostic imaging techniques do not adequately resolve complex Type B and C coronary lesions, which present unique challenges, require personalized treatment and result in worsened patient outcomes. These lesions are often excluded from large-scale non-invasive clinical trials and there does not exist a validated approach to characterize hemodynamic quantities and guide percutaneous intervention for such lesions. This work identifies key biomarkers that differentiate complex Type B and C lesions from simple Type A lesions by introducing and validating a coronary angiography-based computational fluid dynamic (CFD-CA) framework for intracoronary assessment in complex lesions at ultrahigh resolution. Among 14 patients selected in this study, 7 patients with Type B and C lesions were included in the complex lesion group including ostial, bifurcation, serial lesions and lesion where flow was supplied by collateral bed. Simple lesion group included 7 patients with lesions that were discrete, [Formula: see text] long and readily accessible. Intracoronary assessment was performed using CFD-CA framework and validated by comparing to clinically measured pressure-based index, such as FFR. Local pressure, endothelial shear stress (ESS) and velocity profiles were derived for all patients. We validates the accuracy of our CFD-CA framework and report excellent agreement with invasive measurements ([Formula: see text]). Ultra-high resolution achieved by the model enable physiological assessment in complex lesions and quantify hemodynamic metrics in all vessels up to 1mm in diameter. Importantly, we demonstrate that in contrast to traditional pressure-based metrics, there is a significant difference in the intracoronary hemodynamic forces, such as ESS, in complex lesions compared to simple lesions at both resting and hyperemic physiological states [n = 14, [Formula: see text]]. Higher ESS was observed in the complex lesion group ([Formula: see text] Pa) than in simple lesion group ([Formula: see text] Pa). Complex coronary lesions have higher ESS compared to simple lesions, such differential hemodynamic evaluation can provide much the needed insight into the increase in adverse outcomes for such patients and has incremental prognostic value over traditional pressure-based indices, such as FFR.
53
NIH Image to ImageJ: 25 years of image analysis
Caroline A Schneider, Wayne Rasband, Kevin W. Eliceiri · Nature Methods · 2012 · 65.2K citations
LATTICE BOLTZMANN METHOD FOR FLUID FLOWS
Shiyi Chen, Gary D. Doolen · Annual Review of Fluid Mechanics · 1998 · 7.2K citations
Hemodynamic Shear Stress and Its Role in Atherosclerosis
Adel M. Malek · JAMA · 1999 · 3.6K citations
Matthew J. Budoff, David A. Dowe, James G. Jollis et al. · Journal of the American College of Cardiology · 2008 · 2.1K citations
Medicine, Cardiology, Radiology +14