Applied Physics Letters · 2021 · 12 citations · 32 references
EngineeringVibrationsPhysicsHarsh EnvironmentsOptical DiagnosticsSpectroscopyNatural SciencesTemperature MeasurementThermodynamicsInstrumentationOptical SpectroscopyFast Temperature MeasurementBroadband 35-Fs Pulse
We demonstrate a 1-kHz, single-shot, dynamic, and sensitive flame temperature measurement using hybrid femtosecond/picosecond vibrational coherent anti-Stokes Raman scattering. This benefits from a 7-cm−1, 240-μJ, and sideband-free picosecond pulse out of a broadband 35-fs pulse through a quasi-common-path second harmonic bandwidth compressor system. Measurements around optimal time delay exhibit superior performance with a temperature inaccuracy of less than 1% and a precision of ∼2% at 1790 K. These results demonstrate the advantages and potential for the accurate and fast temperature measurement in practical or harsh environments.