Frontiers in Cardiovascular Medicine · 2021 · 18 citations · 10 references
EngineeringBiomedical EngineeringCardiologyBiomedical Signal ProcessingBiosensorsSensorsCardiovascular MonitoringRespiratory MonitoringVital SignsVital Signs AssessmentVital Signs RecordingWearable Health TechnologiesBiomarkersClinical Signs DetectionDigital BiomarkersHeart RateHome Monitoring Vital SignsHome Vital Signs MonitoringPhysiological MonitoringSleep Quality
Home monitoring systems increasingly track seniors for emergencies, and multimodal ambient sensors now detect digital biomarkers over longer periods, while clinical signs of heart‑failure decompensation—elevated heart and respiration rates, reduced activity, slower gait, increased nighttime toileting, and poorer sleep—can be captured by contactless sensors to prevent deterioration and hospitalization. The study demonstrates the feasibility of an affordable, contactless ambient sensor system to detect early signs of.
Home monitoring systems are increasingly used to monitor seniors in their apartments for detection of emergency situations. More recently, multimodal ambient sensor systems are also used to monitor digital biomarkers to detect clinically relevant health problems over longer time periods. Clinical signs of HF decompensation including increase of heart rate and respiration rate, decreased physical activity, reduced gait speed, increasing toilet use at night and deterioration of sleep quality have a great potential to be detected by non-intrusive contactless ambient sensor systems and negative changes of these parameters may be used to prevent further deterioration and hospitalization for HF decompensation. This is to our knowledge the first report about the potential of an affordable, contactless, and unobtrusive ambient sensor system for the detection of early signs of HF decompensation based on data with prospective data acquisition and retrospective correlation of the data with clinical events in a 91 year old senior with a serious heart problem over 1 year. The ambient sensor system detected an increase of respiration rate, heart rate, toilet use at night, toss, and turns in bed and a decrease of physical activity weeks before the decompensation. In view of the rapidly increasing prevalence of HF and the related costs for the health care systems and the societies, the real potential of our approach should be evaluated in larger populations of HF patients.
10
Global Public Health Burden of Heart Failure
Gianluigi Savarese, Lars H. Lund · Cardiac failure review · 2017 · 2.7K citations · Full text
Prabitha Urwyler, Reto Stucki, Luca Rampa et al. · Scientific Reports · 2017 · 124 citations · Full text
EMFIT QS heart rate and respiration rate validation
Jukka Ranta, Timo Aittokoski, M. Tenhunen et al. · Biomedical Physics & Engineering Express · 2019 · 49 citations