Pakistan Journal of Medical Sciences · 2021 · 10 citations · 16 references
EducationKinesiologyPhysical MedicineExercise TestingPhysiatryPhysical TherapyMuscle Strength AssessmentMuscle Strength TestingMuscular StrengthMuscular Strength TestingMusculoskeletal AssessmentPhysical Performance AssessmentHand-held DynamometryInter-rater AgreementInter-rater ReliabilityInter-rater Reliability AssessmentIsometric Muscle Strength TestingLower Limb Muscle Strength AssessmentPairwise ComparisonStrength Testing Reliability
Objective: To determine intra-rater and inter-rater reliability of hand-held dynamometer for assessing isometric lumbar muscle strength in asymptomatic healthy population. Methods: It was a cross-sectional study conducted at the department of physiotherapy, University of Lahore Teaching Hospital, Lahore, Pakistan, from July 2020 to August 2020 through non probability-purposive sampling technique. Thirty healthy subjects were tested at thirty-degree lumbar flexion and zero-degree lumbar extension positions. Two raters assessed isometric strength of lumbar flexor and extensor muscles, by a hand-held dynamometer. Strength was measured and recorded by each of the two raters and re-assessed after a week. Correlation and pairwise comparison were done between readings. ICC values were calculated for the assessment of isometric lumbar muscle strength using handheld dynamometer. Results: A total of 30 healthy subjects had participated with mean age of 22.84±1.21 years, height 174.33±6.83 cm, weight 68.58±5.08 kg and BMI 22.52±0.35. Findings showed an excellent intra-rater (ICC 2, k = 0.95 to 0.97) and inter-rater (ICC 2, k = 0.94 to 0.95) reliability. Conclusions: Hand held dynamometer demonstrated an excellent intra- and inter-rater reliability for assessment of isometric lumbar muscles strength of healthy subject at clinical setting as it is simple to use, portable and cost-effective for the precise measurement of lumbar muscles strength. doi: https://doi.org/10.12669/pjms.37.2.3621 How to cite this:Tanveer F, Arslan SA, Darain H, Ahmad A. Reliability of Hand-Held Dynamometer for assessing Isometric Lumbar Muscles Strength in Asymptomatic Healthy Population. Pak J Med Sci. 2021;37(2):461-465. doi: https://doi.org/10.12669/pjms.37.2.3621 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
16
Normative reference values for strength and flexibility of 1,000 children and adults
Marnee J. McKay, Jennifer Baldwin, Paulo H. Ferreira et al. · Neurology · 2016 · 244 citations · Full text