Influence of Process Parameters and Absorber Thickness on Efficiency of Polycrystalline CdSeTe/CdTe Thin Film Solar Cells

Tushar Shimpi, Carey Reich, Adam Danielson, Amit Munshi, Anna Kindvall, Ramesh Pandey, K. Barth, Walajabad Sampath

2020 · 12 citations · 2 references

Concepts

Abstract

Graded absorbers devices with with CdSe <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.4</sub> Te <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.6</sub> (molar basis) and CdTe were fabricated. CdCl <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> treatment time, post-deposition CdCl <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> anneal time and thicknesses of CdSeTe and CdTe layers were varied. Photoluminescence and electrical measurements were performed on the fabricated devices. Results revealed that the individual thicknesses of CdSeTe and CdTe is critical to overall efficiency of the devices. Device fabricated on substrate with 0.5 μm CdSeTe, 3 μm CdTe with rest of process parameters kept unchanged, produced an efficiency of 20.14%. We report highest device efficiency among academia and research institutions.

References

2