International Journal of Cardiology · 2021 · 80 citations · 16 references
MedicineCardiologyComputer ScienceArtificial IntelligenceClinical CardiologyMachine LearningCardiac AssessmentCardiac Signal ProcessingCardiovascular AssessmentElectrocardiogram AnalysisElectrocardiogram InterpretationElectrocardiographyAsymptomatic Left Ventricular DysfunctionComputer-aided Electrocardiogram InterpretationElectrocardiogram DiagnosisExternal Validation CohortsLeft Ventricular Systolic FunctionSystolic DysfunctionValidation Study DesignVentricular Ejection Fraction Assessment
OBJECTIVE: To validate a novel artificial-intelligence electrocardiogram algorithm (AI-ECG) to detect left ventricular systolic dysfunction (LVSD) in an external population. BACKGROUND: LVSD, even when asymptomatic, confers increased morbidity and mortality. We recently derived AI-ECG to detect LVSD using ECGs based on a large sample of patients treated at the Mayo Clinic. METHODS: We performed an external validation study with subjects from the Know Your Heart Study, a cross-sectional study of adults aged 35-69 years residing in two cities in Russia, who had undergone both ECG and transthoracic echocardiography. LVSD was defined as left ventricular ejection fraction ≤ 35%. We assessed the performance of the AI-ECG to identify LVSD in this distinct patient population. RESULTS: Among 4277 subjects in this external population-based validation study, 0.6% had LVSD (compared to 7.8% of the original clinical derivation study). The overall performance of the AI-ECG to detect LVSD was robust with an area under the receiver operating curve of 0.82. When using the LVSD probability cut-off of 0.256 from the original derivation study, the sensitivity, specificity, and accuracy in this population were 26.9%, 97.4%, 97.0%, respectively. Other probability cut-offs were analysed for different sensitivity values. CONCLUSIONS: The AI-ECG detected LVSD with robust test performance in a population that was very different from that used to develop the algorithm. Population-specific cut-offs may be necessary for clinical implementation. Differences in population characteristics, ECG and echocardiographic data quality may affect test performance.
16
2013 ACCF/AHA Guideline for the Management of Heart Failure
Clyde W. Yancy, Mariell Jessup, Biykem Bozkurt et al. · Journal of the American College of Cardiology · 2013 · 12.6K citations
Global Public Health Burden of Heart Failure
Gianluigi Savarese, Lars H. Lund · Cardiac failure review · 2017 · 2.7K citations · Full text
Clinical Epidemiology: The Essentials.
Annals of Internal Medicine · 1991 · 1.9K citations